Page 90 - FLUID MECHANICS EBOOK FINAL (2)
P. 90

FLUID MECHANICS


                       d.     Inclined Venturi Meter


                              Derivation is an expression for the rate of flow through an inclined venturi meter.

                              This will show that the U-type of gauge is used to measure the pressure difference.
                              The  gauge  reading  will  be  the  same  for  a  given  discharge  irrespective  of  the
                              inclination of the meter.

                              In  Figure  4.10,  at  the  entrance  to  the  meter;  the  area,  velocity,  pressure  and

                              elevation  are  A1,  v1, p1 and  z1 respectively and at the  throat, the  corresponding

                              values are A2, v2, p2 and z2.






                                                                       = spec. wt of
                                                    A2, v2, p2        liquid in pipeline

                                     A1, v1, p1     and z2
                                     and z1








                                                              Spec.wt = g



                         Z1    ( z1-y )
                                                                                     Z2
                                                                         X


                                  y                 P         Q

                                                               Q


                                           Figure 4.10 : Inclined venturi meter