Page 90 - ebook fluid mechanics_finalize
P. 90

FLUID MECHANICS


                       d.     Inclined Venturi Meter


                              Derivation is an expression for the rate of flow through an inclined venturi meter.

                              This will show that the U-type of gauge is used to measure the pressure difference.
                              The  gauge  reading  will  be  the  same  for  a  given  discharge  irrespective  of  the
                              inclination of the meter.

                              In  Figure  4.10,  at  the  entrance  to  the  meter;  the  area,  velocity,  pressure  and

                              elevation  are  A1,  v1, p1 and  z1 respectively and at the  throat, the  corresponding

                              values are A2, v2, p2 and z2.






                                                                       = spec. wt of
                                                    A2, v2, p2        liquid in pipeline

                                     A1, v1, p1     and z2
                                     and z1








                                                              Spec.wt = g



                         Z1    ( z1-y )
                                                                                     Z2
                                                                         X


                                  y                 P         Q

                                                               Q


                                           Figure 4.10 : Inclined venturi meter




















                                                                                                            79
   85   86   87   88   89   90   91   92   93   94   95