             c)  The sample is sieved through BS Standard sieve specified in
                 Table 3.2
             d)  A minimum of 200 pieces of each fraction is taken and
                 weighed.
             e)  In order to separate elongated materials, each fraction is
                 then gauged individually for length in the length gauge.
             f)  The pieces of aggregate from each fraction tested which
                 could not pass through the specified gauge length with its
                 long sides elongated are collected separately to find    the
                 total weight of aggregate retained on the length gauge from
                 each fraction.
             g)  The total amount of elongated material retained by the length
                 gauge is weighed to an accuracy of 0.1% of the weight of
                 sample.



            CALCULATION FOR ELONGATION INDEX TEST



                    Elongation Index (FI) =  Weight retained slot   x 100
                                              Weight Original



               ElongationIndex      =       Total(M2)                 x100
                                            Total (M2) + Total (M3)