                                      WORK PROCESS                                    DOCUMENT

              4. . Heat the water for a minimum of 15 minutes and not more than 30
                   minutes.

              e. Testing of the Specimen:

              1. Remove the collar along with the sample from the base plate.

              2. Place the sample along with the collar to the aluminum float and
                 fix it with a screw.

              3. Immerse this assembly in water for 1 minute at 5 °C.

              4. Take out the assembly from the water and remove the water from
                 inside of the float, if present inside.

              5. Hover the assembly immediately into warm bath prepared
                 previously of temperature about 50 °C ensuring that the collar is
                 tightly attached to the float. No seepage of water should occur at

                 the time of testing between the collar and float.
              6. Take a stopwatch and start the timer as soon as the assembly is

                 introduced into the warm bath.

              7. Note the time in seconds at which the water breaks through the
                 specimen with the help of a stopwatch. This time gives the float
                 value.



             DATA :

             Following observations are to be recorded during the float test of
             bitumen
             (A sample observation table for float test of bitumen is drawn
             below)



                 Observations           Specimen – 1           Specimen – 2

                Time in Second




              Float Value = Average float value of 1 and 2.