3.0  EQUIPMENTS:























                       Penetrometer set           Transfer Dish              Stop Watch              Spatula



             4.0 DETAILED PROCEDURE : FLAKINESS INDEX TEST

                                                                                       REFERENCE
                                      WORK PROCESS
                                                                                      DOCUMENT
              1. The penetration apparatus is specified in many standards

                  throughout the world but has always the same
              2. Specimens are prepared in sample containers and placed in
                  a water bath at the prescribed temperature of test for 1 to 1.5
                  hours before the test.

              3. For normal tests the precisely dimensioned needle, loaded to
                  100 ± 0.05 g, is brought to the surface of the specimen at right
                  angles, allowed to penetrate the bitumen for 5 ± 0.1 s, while
                  the temperature of the specimen is maintained at 25 ± 0.1°C.

                  The penetration is measured in tenths of a millimeter (Deci-
                  millimeter, d-mm).
              4. Make at least three determinations on the specimen. A clean
                  needle is  used for each determination. In making repeat

                  determinations, start each with the tip of the needle at least
                  10 mm from the side of the container and at least 10 mm
                  apart.








                             Apparatus for the bitumen penetrationtest